Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

CiteULike is a free service for managing and discovering scholarly references - click here to get started.

Sign In to gain access to subscriptions and/or personal tools.
Biological Research For Nursing
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Frazier, S. K.
Right arrow Articles by Stone, K. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Frazier, S. K.
Right arrow Articles by Stone, K. S.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Heart Rate Variability and Hemodynamic Alterations in Canines with Normal Cardiac Function during Exposure to Pressure Support, Continuous Positive Airway Pressure, and a Combination of Pressure Support and Continuous Positive Airway Pressure

Susan K. Frazier, RN, PhD

Adult Health & Illness, College of Nursing, The Ohio State University, 1585 Neil Avenue, Office 372, Columbus, OH 43210; phone: (614) 292-4991; fax: (614) 292-7976.

Debra K. Moser, RN, DNSc

Kathleen S. Stone, RN, PhD, FAAN

Department of Adult Health & Illness at The Ohio State University.

Variations in intrathoracic pressure generated by different ventilator weaning modes may significantly affect intrathoracic hemodynamics and cardiovascular stability. Although several investigators have attributed cardiovascular alterations during ventilator weaning to augmented sympathetic tone, there is limited investigation of changes in autonomic tone during ventilator weaning. Heart rate variability (HRV), the analysis of beat-to-beat changes in heart rate, is a noninvasive indicator of autonomic tone that might be useful in the identification of patients who are at risk for weaning difficulty due to underlying cardiac dysfunction. The authors describe HRV and hemodynamics in response to 3 ventilatory conditions: pressure support (PS) 10 cmH2O, continuous positive airway pressure (CPAP) 10 cmH2O, and a combination of PS 10 cmH2O and CPAP 10 cmH2O (PS+CPAP) in a group of canines with normal ventricular function. Six canines were studied in the laboratory. Continuous 3-lead electrocardiographic data were collected during baseline (controlled mechanical ventilation) and following transition to each of the ventilatory conditions (PS, CPAP, PS+CPAP) for analysis of HRV. HRV was evaluated using power spectral analysis to define the power under the curve in a very low frequency range (0.0033 to < 0.04 Hz, sympathetic tone), a low frequency range (0.04 to < 0.15 Hz, primarily sympathetic tone), and a high frequency range (0.15 to < 0.40 Hz, parasympathetic tone). A thermodilution pulmonary artery catheter measured cardiac output and right ventricular end-diastolic volume to describe global hemodynamics. There were significant increases in very low frequency power (sympathetic tone) with a concomitant significant reduction in high-frequency power (parasympathetic tone) with exposure to PS+CPAP. These alterations in HRV were associated with significantly increased heart rate and reduced right ventricular end-diastolic volume. Although there was a small but significant increase in cardiac output with exposure to PS, HRV was unchanged. These data indicate that there was a relative shift in autonomic balance to increased sympathetic and decreased parasympathetic tone with exposure to PS+CPAP. The increase in intrathoracic pressure reduced right ventricular end-diastolic volume (preload). This hemodynamic alteration generated a change in autonomic tone, so that cardiac output could be maintained. Individuals with autonomic and/or cardiovascular dysfunction may not be capable of this type of response and may fail to successfully wean from mechanical ventilation.

Key Words: Heart rate variability • power spectral analysis • cardiac output • right ventricular end-diastolic volume • pressure support • continuous positive airway pressure • mechanical ventilation • ventilator weaning

Biological Research For Nursing, Vol. 2, No. 3, 167-174 (2001)
DOI: 10.1177/109980040100200302


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
Biol Res NursHome page
S. K. Frazier, D. K. Moser, R. Schlanger, J. Widener, L. Pender, and K. S. Stone
Autonomic Tone in Medical Intensive Care Patients Receiving Mechanical Ventilation and During a CPAP Weaning Trial
Biol Res Nurs, April 1, 2008; 9(4): 301 - 310.
[Abstract] [PDF]


Home page
ChestHome page
H.-N. Shen, L.-Y. Lin, K.-Y. Chen, P.-H. Kuo, C.-J. Yu, H.-D. Wu, and P.-C. Yang
Changes of Heart Rate Variability During Ventilator Weaning
Chest, April 1, 2003; 123(4): 1222 - 1228.
[Abstract] [Full Text] [PDF]


Home page
Am J Crit CareHome page
S. L. Smith
Heart Period Variability of Intubated Very-Low-Birth-Weight Infants During Incubator Care and Maternal Holding
Am. J. Crit. Care., January 1, 2003; 12(1): 54 - 64.
[Abstract] [Full Text] [PDF]